David did a great job for us today. Personal and professional.
Sprinkler, Kitchen Suppression, and Portable Extinguishers Inspection Wet Access Panel: Annual Fire Sprinkler Inspection Pyro Chem Kitchen knight II 300 Kitchen: Semi-annual Kitchen Hood System Inspection - Pyrochem Annual Fire Extinguisher Inspection Deficiency for Wet Access Panel: 165 head semi front door bathroom Unit 101 155 chrome semi paint Unit 102 155 chrome semi paint 2nd floor 215 (2) 165 semi chrome corroded FDC and PIV signs faded Deficiency: Customer has requested a quote to replace (1) 6L K type and do (1) 6 year tear down that is inside elevator room. K type is leaking and has lost a good amount of weight recommend to just replace unit Abc is past due annual and 6 year tear down Total items : (1) new 6L k type (1) 6 year tear down (1) disposal fee (2) annuals (1) trip charge
Portable Extinguishers Service Call Deliver and install new fire extinguishers to office. Deficiency: Customer needs a quote for exit lights, customer needs (4) green LED powered exit lights hard wired inside, customer will be responsible to pre wire where exit lights to be installed, amd Aztec will install new lights in place. Installing exit lights onto dry wall and wood paneling, possibly have to run wires exposed inside conduit to a dedicated breaker on the breaker box. Need to install on the very back door to the back patio area, Need to install one on the hallway headed towards the back door, and need to install (2) one above each entry way Total items : (4) new green LED exit lights (4) install of exit lights (1) trip charge Deficiency: Customer needs to be add (2) “ Doors must remain open at all times when open” signs above both front entry ways. Total items : (2) “doors must remain open” signs (2) installs (1) trip charge
Pyro Chem Kitchen knight II 300 Kitchen: Semi-annual Kitchen Hood System Inspection - Pyrochem
Portable Extinguishers Service Call Service Call: Recharge 3 fire extinguishers used. Called in by Juan. Deficiency: Photos uploaded - all fes appear to be overdue
Portable Extinguishers Inspection Annual Fire Extinguisher Inspection
Sprinkler Inspection Quarterly Fire Sprinkler Inspection *
Portable Extinguishers Inspection Annual Fire Extinguisher Inspection
Portable Extinguishers Inspection Annual Fire Extinguisher Inspection